Value¶
SCPI Commands
CONFigure:DATA:CONTrol:IMS<Ims>:SIP:TIMer:VALue
- class Value[source]
Value commands group definition. 1 total commands, 0 Sub-groups, 1 group commands
- get(ims=<Ims.Default: -1>) → int[source]
# SCPI: CONFigure:DATA:CONTrol:IMS<Suffix>:SIP:TIMer:VALue value: int = driver.configure.data.control.ims.sip.timer.value.get(ims = repcap.Ims.Default)
Sets SIP timer T1 for custom mode, see method RsCmwDau.Configure.Data.Control.Ims.Sip.Timer.Case.Selection.set.
- param ims
optional repeated capability selector. Default value: Ix1 (settable in the interface ‘Ims’)
- return
sip_timer_value: Range: 10 ms to 600E+3 ms, Unit: ms
- set(sip_timer_value: int, ims=<Ims.Default: -1>) → None[source]
# SCPI: CONFigure:DATA:CONTrol:IMS<Suffix>:SIP:TIMer:VALue driver.configure.data.control.ims.sip.timer.value.set(sip_timer_value = 1, ims = repcap.Ims.Default)
Sets SIP timer T1 for custom mode, see method RsCmwDau.Configure.Data.Control.Ims.Sip.Timer.Case.Selection.set.
- param sip_timer_value
Range: 10 ms to 600E+3 ms, Unit: ms
- param ims
optional repeated capability selector. Default value: Ix1 (settable in the interface ‘Ims’)