Selection

SCPI Commands

CONFigure:DATA:CONTrol:IMS<Ims>:SIP:TIMer:CASE:SELection
class Selection[source]

Selection commands group definition. 1 total commands, 0 Sub-groups, 1 group commands

get(ims=<Ims.Default: -1>)RsCmwDau.enums.SipTimerSel[source]
# SCPI: CONFigure:DATA:CONTrol:IMS<Suffix>:SIP:TIMer:CASE:SELection
value: enums.SipTimerSel = driver.configure.data.control.ims.sip.timer.case.selection.get(ims = repcap.Ims.Default)

Selects a configuration mode for SIP timer T1.

param ims

optional repeated capability selector. Default value: Ix1 (settable in the interface ‘Ims’)

return

sip_timer_sel: DEFault | RFC | CUSTom DEFault: 3GPP TS 24.229 (2000 ms) RFC: RFC 3261 (500 ms) CUSTom: method RsCmwDau.Configure.Data.Control.Ims.Sip.Timer.Value.set

set(sip_timer_sel: RsCmwDau.enums.SipTimerSel, ims=<Ims.Default: -1>)None[source]
# SCPI: CONFigure:DATA:CONTrol:IMS<Suffix>:SIP:TIMer:CASE:SELection
driver.configure.data.control.ims.sip.timer.case.selection.set(sip_timer_sel = enums.SipTimerSel.CUSTom, ims = repcap.Ims.Default)

Selects a configuration mode for SIP timer T1.

param sip_timer_sel

DEFault | RFC | CUSTom DEFault: 3GPP TS 24.229 (2000 ms) RFC: RFC 3261 (500 ms) CUSTom: method RsCmwDau.Configure.Data.Control.Ims.Sip.Timer.Value.set

param ims

optional repeated capability selector. Default value: Ix1 (settable in the interface ‘Ims’)